Accessories

Diesel Engine Driven Fire Pump Sets

Exhaust System – High-Performance Exhaust Expansion made of Stainless Steel


High-performance exhaust expansion allows the absorption of axial and radial offset of the pipes caused by temperature expansion, and facilitates the installation of the connected exhaust pipes. As a rule, installations with fixed connections and additional compensating joints are no longer needed.

  • with shaped connection suitable for the diesel engine
  • with companion flange of the corresponding nominal diameter
  • including screws and nuts
  • exhaust gasket with high temperature stability
  • integrated, galvanized telescopic protection against accidental contact

Heat insulated Wall Duct


  • designed as a fixed point mounting to facilitate the installation of the pipes
  • nominal diameter as required
  • with external mounting plate with weather protection and gullet
  • escape pipe with integrated bird protection screen and water return stop
  • completely hot-dip galvanized

Heat insulated Roof Duct


  • with mounting flange suitable to be glued into the vapour seal
  • designed as a fixed point mounting to facilitate the installation of the pipes
  • nominal diameter as required
  • escape pipe with integrated bird protection and water return stop
  • Special design with external flange to be connected to the continuing exhaust piping.
  • completely hot-dip galvanized

Diesel Fuel Tank Systems


We manufacture

  • diesel fuel tanks with capacities from 180 to 5000 liters
  • with 100% drip pan
  • for floor or wall mounting
  • designed to meet all official regulations
  • suitable as storage or main storage tank
  • optionally with manual transfer pump devices to the diesel fuel service tanks on the pump units
  • with leak detector and all other fittings
  • The drip pans are always hot-dip glavanized as protection against corrosion but can also be painted (optional)

Double wall fuel tanks (750-2000 litres)


Kraftstofftank750l_doppelwandig

  • leak detection by a type tested, approved, completely assembled and calibrated vacuum leak detector
  • dimensions optimized and suitable for the installation conditions
  • floor racks in different heights matching the respective diesel engine

Leakage Monitoring Base Frame Drip Pan


Integrated into the drip pan of the base frame to indicate leakages of the diesel fuel tank and /or the diesel engine. With potential free contacts for external signal processing.

Manually operated Diaphragm Pump DN 40


  • high performance
  • with double check valve
  • complete pipe connection to the diesel fuel tank at the discharge side
  • with diesel fuel resistant suction tube at the suction side for extraction from a barrel, length dimensioned amply
  • support for suction tube

Room Ventilation by Louvers


  • air intake and exhaust air louver with actuating drive
  • installation inside the room with a suitable mounting frame
  • including power supply and opening and closing control
  • with test pushbutton on the diesel controller (not in general)
  • design and dimensions dependent on the corresponding pump unit
  • separate weather protection grids made of aluminium extruded sections, bird protection screen
  • installation on the outside wall with a suitable mounting frame
  • on request also available in all RAL-colours suitable for outside walls with powder coating

Room Ventilation by Exhaust Fan


  • air intake louver with actuating drive
  • installation inside the room with a suitable mounting frame
  • including power supply and opening and closing control
  • with test pushbutton on the diesel controller (not in general)
  • manually operated emergency switch for the actuators
  • design and dimensions dependent on the corresponding pump unit
  • separate weather protection grids made of aluminium extruded sections, bird protection screen
  • installation on the outside wall with a suitable mounting frame
  • on request also available in all RAL-colours suitable for outside walls with powder coating
  • exhaust fan with motor 12/24 V DC
  • 400 mm diameter
  • volume flow 3.550 m³/h
  • with protection grid in accordance with GSG
  • galvanized mounting plate
  • mains-independent power supply, controlled from the diesel controller
  • battery group with higher performance
  • higher alternator performance
  • with room thermostat IP 54 for exhaust fan to start only if room temperature is increased
  • flutter jalousie for exhaust fan delivered separately

Accessories for Room Ventilation Sets in Special Design ‘SCHALL-EX’


Exhaust Fan with Attenuator tuned to the Sound Spectrum of the Pump Set

  • insertion loss, nominal diameter and length according to the requirements at site
  • with wall mounting flange made of hot-dip galvanized steel sections, with drill holes for fastening
  • exhaust air side with mounted flutter jalousie
  • including mounting brackets for ceiling suspension
  • exhaust fan installed inside the room

Air Intake Louvre with Attenuator tuned to the Sound Spectrum of the Pump Set

  • insertion loss, nominal diameter and length according to the requirements at site
  • with wall mounting flange made of hot-dip galvanized steel sections, with drill holes for fastening
  • air intake side with mounted flutter jalousie
  • including mounting brackets for ceiling suspension
  • with flutter jalousie inside the room
  • separate weather protection grid made of aluminium extruded sections and bird protection screen with mounting flanges to be installed to the outside wall

Room Ventilation by Air Cooling Unit


Especially designed for pump stations without any wall openings to the outside or located below ground, thus without any possibility to install a regular, mains-independent and cost-saving ventilation system.

The air cooling unit, especially adjusted to the heat radiation of the corresponding diesel engine, withdraws the heat radiation of the diesel engine from the air and transfers this heat via partial flow back to the water storage tank.

  • mains-independent power supply, controlled from the diesel controller
  • with room thermostat IP 54 for exhaust fan to start only if room temperature is increased

Only a very small amount of water will be taken from the pump via connection with a solenoid valve. This system represents a highly efficient and cost-saving solution to the problem of cooling a pump station sufficiently.

Fastening Set


Complete fastening set with all accessories necessary fro the quick, professional and cost effective fastening of the pump set.

Pressure Gauge Assembly for Suction and Discharge Side of the Pump


  • pressure / vacuum gauge assembly for suction side of the pump
  • pressure gauge assembly for discharge side of the pump
  • in accordance with the NFPA Standard
  • stainless steel case
  • with glycerine filling
  • accuracy class 1,0
  • dual scale bar/PSI
  • stop valve with bleeder connection and hose (with tightening strap) 300 mm and screw connection
  • pipe socket to be screwed down into the connecting sleeve

Design ‘SCHALL-EX’ for Structure-Borne Noise Deadening Installation of the Pump Set


  • with pre-fabricated steel foundation made of steel sections, electrically welded and hot-dip galvanized
  • for structure-borne noise deadening installation to a sufficiently stable bearing plate
  • with elastomers with a shore hardness of 25 – 60 as required
  • including 2 fastening sets type ‘A’ to fasten the pre-fabricated steel foundation to the bearing plate