{"id":836,"date":"2020-11-23T14:35:04","date_gmt":"2020-11-23T13:35:04","guid":{"rendered":"https:\/\/www.holzhauer-pumpen.de\/en\/?post_type=projects&p=836"},"modified":"2026-04-01T11:59:16","modified_gmt":"2026-04-01T09:59:16","slug":"noise-insulated-fire-fighting-unit","status":"publish","type":"projects","link":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit","title":{"rendered":"Noise insulated fire fighting unit"},"content":{"rendered":"\n

Our client is responsible for the agricultural business of a group that operates in the fields of seeds, plant protection and professional pest control.<\/p>\n\n\n\n

Requirements<\/h2>\n\n\n\n

Our customer employs around 620 people at Industriepark H\u00f6chst, some of whom handle flammable chemicals. The new fire extinguishing system not only had to be mains-independent and powerful, but also comply with the noise and vibration occupational health and safety regulations. At the same time, it had to take into account that in Hesse, medium-strong earthquakes occur about once every ten years, which can cause building damage and operational disruptions. Challenging requirements that we mastered with greatest skill!<\/p>\n\n\n\n

Solution<\/h2>\n\n\n\n

Silenced capsule around the diesel engine and fire pump, with inspection openings for easy maintenance of the system. The engine’s operating indicators and controls, as well as the switchgear and heat exchanger, are also located outside the capsule. The exhaust fans are thermostatically controlled and designed for the heat radiation of the diesel engine in the sound insulation capsule. The entire system has a static certification for earthquake resistance.<\/p>\n\n\n\n

Project Details<\/h2>\n\n\n\n
Category<\/td>Scientific research<\/td><\/tr>
Launch<\/td>2017<\/td><\/tr>
Max. Output<\/td>13,333 litres \/ minute <\/td><\/tr>
Operating Pressure<\/td>12 bar<\/td><\/tr>
Sound pressure at one metre distance<\/td>83.3 dB<\/td><\/tr><\/tbody><\/table><\/div><\/div><\/figure>\n\n\n\n

<\/p>\n\n\n\n

\n
<\/div>
<\/div>

You are currently viewing a placeholder content from YouTube<\/strong>. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.<\/p> More Information<\/a> <\/div>

Unblock content<\/a> Accept required service and unblock content<\/a> <\/div> <\/div> <\/div><\/div>\n<\/div><\/figure>\n\n\n
\n \n
\n
\n
\n\t \t
\n
\n \n \"\"\n <\/a>\n <\/div>\n <\/div>\n \t
\n
\n \n \"\"\n <\/a>\n <\/div>\n <\/div>\n \t
\n
\n \n \"\"\n <\/a>\n <\/div>\n <\/div>\n \t
\n
\n \n \"\"\n <\/a>\n <\/div>\n <\/div>\n <\/div>\n
<\/div>\n
\n
<\/div>\n
<\/div>\n <\/div>\n <\/div>\n <\/div>\n<\/section>\n\n\n
\n\n
\n
\n

\n More Reference Projects <\/h2>\n <\/div>\n <\/div>\n \n
\n
\n
\n
\n \n \"\"\n
\n

Power Plants and Recycling<\/p>\n

\n Fire protection for Energiek\u00fcste LNG terminal <\/h3>\n

Requirements The LNG terminal in northern Germany is a strategically important infrastructure project for Germany’s energy supply. As part of the \u201cEnergy Coast\u201d, the\u2026<\/p>\n

\n \n <\/path><\/svg>\n <\/span>\n <\/p>\n <\/div>\n <\/a>\n <\/article>\n \"\"\n

\n

Power Plants and Recycling<\/p>\n

\n Fire protection for the dismantling of the nuclear power plant <\/h3>\n

Requirements Fire protection is a key issue when dismantling nuclear power plants. Our specially developed fire protection unit meets all safety-related requirements and is\u2026<\/p>\n

\n \n <\/path><\/svg>\n <\/span>\n <\/p>\n <\/div>\n <\/a>\n <\/article>\n \"\"\n

\n

Retail<\/p>\n

\n Stationary fire protection solution for Berlin shopping center <\/h3>\n

Requirements Shopping centers place complex demands on stationary fire protection systems. The aim of this project was to plan, manufacture, supply and install a\u2026<\/p>\n

\n \n <\/path><\/svg>\n <\/span>\n <\/p>\n <\/div>\n <\/a>\n <\/article>\n <\/div>\n

\n \n Show all projects <\/a>\n <\/div>\n <\/div>\n <\/div>\n <\/section>\n\n\n
\n\t
\n

Let us help you!<\/h2>\n <\/div>\n\t\t
\n

Our employees explain and illustrate the requirements of standards and regulations as early as the initial consultation phase and thus facilitate the implementation and safe application in your daily work. In addition, they present engineering expertise spanning 50 years of hands-on application and research and thus provide our customers with a decisive competitive edge.<\/p>\n <\/div>\n\t

\n

\n \n\t Contact us <\/a>\n <\/p>\n <\/div>\n <\/section>\n","protected":false},"excerpt":{"rendered":"

Our customer employs around 620 people at Industriepark H\u00f6chst, some of whom handle flammable chemicals.<\/p>\n","protected":false},"featured_media":5961,"template":"","class_list":["post-836","projects","type-projects","status-publish","has-post-thumbnail","hentry"],"yoast_head":"\nNoise insulated fire fighting unit - Holzhauer-Pumpen GmbH<\/title>\n<meta name=\"description\" content=\"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Noise insulated fire fighting unit - Holzhauer-Pumpen GmbH\" \/>\n<meta property=\"og:description\" content=\"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit\" \/>\n<meta property=\"og:site_name\" content=\"Holzhauer-Pumpen GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/holzhauerpumpen\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-01T09:59:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.holzhauer-pumpen.de\/en\/wp-content\/uploads\/sites\/2\/2020\/11\/Kapsel-750.png\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit\",\"url\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit\",\"name\":\"Noise insulated fire fighting unit - Holzhauer-Pumpen GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2020\\\/11\\\/Kapsel-750.png\",\"datePublished\":\"2020-11-23T13:35:04+00:00\",\"dateModified\":\"2026-04-01T09:59:16+00:00\",\"description\":\"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit#primaryimage\",\"url\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2020\\\/11\\\/Kapsel-750.png\",\"contentUrl\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2020\\\/11\\\/Kapsel-750.png\",\"width\":750,\"height\":900},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/about-us\\\/reference-projects\\\/noise-insulated-fire-fighting-unit#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Noise insulated fire fighting unit\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/\",\"name\":\"Holzhauer-Pumpen GmbH\",\"description\":\"Fire protection. Since 1969.\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#organization\",\"name\":\"Holzhauer-Pumpen GmbH\",\"url\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/placeholder.jpg\",\"contentUrl\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/placeholder.jpg\",\"width\":768,\"height\":454,\"caption\":\"Holzhauer-Pumpen GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.holzhauer-pumpen.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/holzhauerpumpen\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/holzhauer-pumpen\\\/mycompany\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC4t3JItgraIywBYYI5Lm7xQ\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Noise insulated fire fighting unit - Holzhauer-Pumpen GmbH","description":"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit","og_locale":"en_US","og_type":"article","og_title":"Noise insulated fire fighting unit - Holzhauer-Pumpen GmbH","og_description":"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.","og_url":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit","og_site_name":"Holzhauer-Pumpen GmbH","article_publisher":"https:\/\/www.facebook.com\/holzhauerpumpen","article_modified_time":"2026-04-01T09:59:16+00:00","og_image":[{"width":750,"height":900,"url":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-content\/uploads\/sites\/2\/2020\/11\/Kapsel-750.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit","url":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit","name":"Noise insulated fire fighting unit - Holzhauer-Pumpen GmbH","isPartOf":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit#primaryimage"},"image":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit#primaryimage"},"thumbnailUrl":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-content\/uploads\/sites\/2\/2020\/11\/Kapsel-750.png","datePublished":"2020-11-23T13:35:04+00:00","dateModified":"2026-04-01T09:59:16+00:00","description":"Sound-insulated enclosure around the diesel engine and fire pump, with inspection openings for easy maintenance of the system.","breadcrumb":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit#primaryimage","url":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-content\/uploads\/sites\/2\/2020\/11\/Kapsel-750.png","contentUrl":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-content\/uploads\/sites\/2\/2020\/11\/Kapsel-750.png","width":750,"height":900},{"@type":"BreadcrumbList","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/about-us\/reference-projects\/noise-insulated-fire-fighting-unit#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.holzhauer-pumpen.de\/en\/"},{"@type":"ListItem","position":2,"name":"Noise insulated fire fighting unit"}]},{"@type":"WebSite","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#website","url":"https:\/\/www.holzhauer-pumpen.de\/en\/","name":"Holzhauer-Pumpen GmbH","description":"Fire protection. Since 1969.","publisher":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.holzhauer-pumpen.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#organization","name":"Holzhauer-Pumpen GmbH","url":"https:\/\/www.holzhauer-pumpen.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.holzhauer-pumpen.de\/wp-content\/uploads\/2020\/12\/placeholder.jpg","contentUrl":"https:\/\/www.holzhauer-pumpen.de\/wp-content\/uploads\/2020\/12\/placeholder.jpg","width":768,"height":454,"caption":"Holzhauer-Pumpen GmbH"},"image":{"@id":"https:\/\/www.holzhauer-pumpen.de\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/holzhauerpumpen","https:\/\/www.linkedin.com\/company\/holzhauer-pumpen\/mycompany\/","https:\/\/www.youtube.com\/channel\/UC4t3JItgraIywBYYI5Lm7xQ"]}]}},"_links":{"self":[{"href":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-json\/wp\/v2\/projects\/836","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-json\/wp\/v2\/projects"}],"about":[{"href":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-json\/wp\/v2\/types\/projects"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-json\/wp\/v2\/media\/5961"}],"wp:attachment":[{"href":"https:\/\/www.holzhauer-pumpen.de\/en\/wp-json\/wp\/v2\/media?parent=836"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}