Our employees explain and illustrate the requirements of standards and regulations already in consultation meetings and thus facilitate the implementation and safe application in daily work. In addition, they present engineering know-how from 50 years of practice as well as research and thus provide our customers with a decisive competitive advantage.

Contact us!

Diesel Fire Fighting Units

Holzhauer Pumpen GmbH
  • NFPA
  • / Diesel Fire Fighting Units

Diesel Fire Fighting Units

Space-saving with high performance, plug&play, no cabling effort, reduced structure-borne noise and only a few interfaces.

Contact us

Compromiseless fire protection.

The advantages of our compact diesel fire pump units: Space-saving with high performance, plug&play, no wiring required, reduced structure-borne noise and few interfaces.

Our customers benefit from the reduction to one single interface in order processing, significantly minimised effort due to:

  • Established processes and partnerships ensure solution-oriented engineering and on-time material procurement.
  • Our technicians are highly competent, friendly and weatherproof when installing and maintaining our systems, including offshore.
  • Due to our close cooperation with international insurers, we always find a safe solution during inspections.
  • Our documentation is precise, understandable and functional.

We are a system supplier and NFPA member.

Base Frame
Base Frame
  • made of self-developed edge profiles
  • completely hot-dip galvanised in a full bath, according to DIN EN ISO 1461 with a protection duration class C3
  • Due to steel sheets with increased material strength and corresponding construction, a considerably higher torsional stiffness is achieved than with comparable sectional steel base frames
  • with integrated drip tray design tested according to AwSV (WHG), including type plate
  • Capacity 100% of tank contents, engine lubricants and engine cooling water/glycol mixture in accordance with the technical guidelines for flammable liquids (TRbF) and the Water Resources Act AwSV (WHG)
  • On request divided for better handling on the construction site

On request with SCHALLEX – structure-borne sound insulation

External Mounting Brackets
External Mounting Brackets
  • external, easy and time-saving installation
  • installation with special fastening accessories without displacement of the pump set
  • integrated center holes as loading points for crane/transport
Jackscrews
Jackscrews
  • For easy alignment of the pump set
Controller
Controller
  • NFPA controller with wall mounting flanges
  • FM approved and / or UL listed
Diesel Fuel Tank System
Diesel Fuel Tank System
  • with minimum level monitoring switch which can be checked externally
  • with level indicator below the safety isolating valve and scale with units in litres
  • fuel shut-off valve with electrical monitoring device

Further information on our Diesel Fuel Tank Systems

Elastic Mounting of the Diesel Engine
Elastic Mounting of the Diesel Engine
  • elastic mounting of the diesel engine combined with a highly flexible coupling to ensure structure-borne noise reduction
Stainless Steel Exhaust Expansion
Stainless Steel Exhaust Expansion
  • with shaped connection suitable for the diesel engine
  • with socket piece of the corresponding nominal diameter
  • with exhaust gas probe facility
  • with chamfered edges to facilitate welding to the connected exhaust pipe
Heat Insulated Roof Duct
Heat Insulated Roof Duct
  • with mounting flange suitable to be glued into the vapour seal
  • designed as a fixed point mounting to facilitate the installation of the pipes
  • nominal diameter as required
  • escape pipe with integrated bird protection screen and water return stop
  • completely hot-dip galvanized
Heat Insulated Wall Duct
Heat Insulated Wall Duct
  • designed as a fixed point mounting to facilitate the installation of the pipes
  • nominal diameter as required
  • with external mounting plate with weather protection and gullet
  • escape pipe with integrated bird protection screen and water return stop
  • completely hot-dip galvanized
Battery System
Battery System
  • completely maintenance-free, sealed starter battery system type OGI with an expected lifetime of 12 years
  • elastic, vibration dampened placement of the battery trays
  • battery wiring with completely insulated wire ends and connection pieces
  • colour coded “+” and “” cables
  • copper earth tapes with increased cross section to facilitate the earth connections
Foot Valves
Foot Valves
  • With or without flat suction basket, completely hot-dip galvanised
Laser Adjustment
Laser Adjustment
  • Each unit will be tested using laser-optics and finely adjusted before delivery.
  • Metal spacers for fine adjustment in different thicknesses compensate alignment errors and allow re-adjustment after installation and during start-up.
  • An Adjustment Protocol is always included in the scope of delivery.

Applications

Reference Projects

Did you know …

We had already installed our company-owned QCTS Quality Control and Test System to ensure the highest product quality back in 1979.

Let us help you!

Our employees explain and illustrate the requirements of standards and regulations already in consultation meetings and thus facilitate the implementation and safe application in daily work. In addition, they present engineering know-how from 50 years of practice as well as research and thus provide our customers with a decisive competitive advantage.