Our employees explain and illustrate the requirements of standards and regulations already in consultation meetings and thus facilitate the implementation and safe application in daily work. In addition, they present engineering know-how from 50 years of practice as well as research and thus provide our customers with a decisive competitive advantage.

Contact us!

Diesel Exhaust Aftertreatment

Holzhauer Pumpen GmbH

Diesel Exhaust Aftertreatment

Modular passive exhaust gas aftertreatment system with continuous regeneration, for use with Holzhauer-Pumpen fire-fighting diesel engines according to VdS or NFPA/FM regulations.

Contact us

With continuous regeneration.

As a complete unit ready for operation and installation for operation without additional auxiliary energy. The unit is equipped with one inlet and one outlet connection and can be integrated directly into the flue gas pipe system.

The filter inserts can be removed for maintenance without dismantling the housing. With complete thermal insulation and galvanised sheet steel cladding.

System performance

  • Particle separation > 99.8 % (particle count measurement)
  • CO reduction > 90%
  • Soot number according to BOSCH < 0.5
  • HCHO-formaldehyde up to 90%
  • Reduction of exhaust gas temperature min. 350°C (filter inlet)

Expected emission data

  • CO carbon monoxide < 30 mg/mÂł*
  • Soot < 3 mg/mÂł*

*Values are based on exhaust gas volume flow at 5 vol.% residual oxygen

The system consists of sintered ceramic filter inserts with upstream oxidation catalysts in the required number and a safety bypass device to ensure the unrestricted operational readiness of the fire pump for the extinguishing duration even in the event of filter saturation resulting from possible motor malfunctions.

The passive particle filters are VERT approved by TRGS 554, BAFU, EMPA, Switzerland.

The unit is monitored electronically. All fault conditions are logged with all necessary data and can be read out. Faults are displayed on the pump control cabinet and are also available as a potential-free signalling contact for forwarding to a manned position.

The system is self-cleaning and does not require any maintenance by the system operator if it is operated properly and in accordance with its intended use and if the prescribed engine lubricants and fuels are used.

Fixing points for ceiling suspension on elevation are provided as standard.


Applications

Reference Projects

Did you know …

Operators of commercially used buildings are usually required to take out a fire insurance policy.

Let us help you!

Our employees explain and illustrate the requirements of standards and regulations as early as the initial consultation phase and thus facilitate the implementation and safe application in your daily work. In addition, they present engineering expertise spanning 50 years of hands-on application and research and thus provide our customers with a decisive competitive edge.